Holger Vogt
fac1d3a79c
ASRC (B-Source) error message is cryptic, as it does not tell
...
which B-Source failed.
Add a hint to the ASRC error message on the name of the
B-Source instance.
2021-09-29 20:19:38 +02:00
Holger Vogt
4667a74389
Adapt gtkwave plotting to the various OSs.
...
macOS still needs some improvement.
2021-09-29 20:19:19 +02:00
Holger Vogt
18478380ad
Revise the SOA and add new parameters:
...
pd_max id_max idr_max te_max rth_ext derating
rth_ext is currently not used
2021-09-29 20:17:55 +02:00
Holger Vogt
3f322e1954
Add a check for sys/sysctrl.h, which has been declared deprecated,
...
and which may not be available (in the future) on some systems.
2021-09-29 20:17:23 +02:00
Holger Vogt
3b245ddd82
VDMOS, prepare SOA with new parameters
...
Model parameters pd_max, id_max, idr_max, and te_max
(power dissipated, drain current, drain reverse current, temperature)
2021-09-29 20:17:03 +02:00
Holger Vogt
aeafe4bd49
Update to the optran circuit examples:
...
TLV9002-test.cir: Rely on optran from spinit
TLV6001-test.cir: Override optran from spinit
2021-09-29 20:16:32 +02:00
Holger Vogt
4a1f7f950c
spinit: add optran to the standard inits
2021-09-29 20:16:09 +02:00
Holger Vogt
00f530c9cb
Add MOS model cards
2021-09-29 20:15:55 +02:00
Holger Vogt
7c84e3f993
SOA for bipolar
...
Replace pow_max by pd_max
2021-09-29 20:15:41 +02:00
Holger Vogt
f06496c912
Enable command 'optran' in spinit or .spiceinit,
...
when the circuit is not yet loaded.
Then the optran data are stored in static variables,
until optran is called again with arg NULL from inp.c,
to set the data in ft_curckt->ci_defTask.
2021-09-29 20:15:13 +02:00
Holger Vogt
a225ce2aaf
List definition needs spaces between ( and next token,
...
and between token and )
Update to comment.
2021-09-29 20:14:45 +02:00
Holger Vogt
04080c2ab3
Add short description of the new examples
2021-09-29 20:14:26 +02:00
Holger Vogt
f40e6b9357
Linux line endings (LF only)
2021-09-29 20:14:17 +02:00
Holger Vogt
70ba37b149
Example OpAmp which converge for op only with optran:
...
TLV6001 and TLV9002
2021-09-29 20:14:05 +02:00
Holger Vogt
b20ac16093
remove old files
2021-09-29 20:13:53 +02:00
Holger Vogt
03d956cbfa
Example file with three dual opamp filters.
...
Different opamps: TL072, OPA1656, OPA1612
2021-09-29 20:13:35 +02:00
Holger Vogt
8dcb1f901a
Three OpAmp Example for optran
2021-09-29 20:13:18 +02:00
Holger Vogt
8c5c8da2a7
line endings LF (Linux)
2021-09-29 20:13:04 +02:00
Holger Vogt
493cf73f7f
optran is only selected when the 'optran' command has been processed.
...
If not, the call to the OPtran() function returns the previous
'converged' value.
2021-09-29 20:12:52 +02:00
Holger Vogt
7f1fdd3934
Don't do optran, if command optran is not given.
2021-09-29 20:12:31 +02:00
Holger Vogt
711157e85d
Update comment: 0 is no initial iteration
2021-09-29 20:12:03 +02:00
Holger Vogt
f0cb886af1
Add command 'write_ic'
...
Write out the right hand side status of the matrix in format
.ic = V(node_xx)
This may be possible at the end of a simulation or after a 'stop'
of the simulation, which may be resumed again afterwars. This
status may be used to start another simulation with these
parameters by inluding into the netlist.
2021-09-29 20:11:45 +02:00
Holger Vogt
0e72287af7
Add command 'write_ic'
...
Write out the right hand side status of the matrix in format
.ic = V(node_xx)
This may be possible at the end of a simulation or after a 'stop'
of the simulation, which may be resumed again afterwars. This
status may be used to start another simulation with these
parameters by inluding into the netlist.
2021-09-29 20:11:13 +02:00
Holger Vogt
893ce7879f
Clarify use of 'optran' command
2021-09-29 20:10:38 +02:00
Holger Vogt
2ef3f66f96
if 'set ngdebug' print out transient initial conditions also with UIC set.
2021-09-29 20:10:25 +02:00
Holger Vogt
41ead284f3
make the error detection work properly
2021-09-29 20:10:02 +02:00
Holger Vogt
ec986b3fbc
Add optran.c
...
New custom build commands as suggested by VS
2021-09-29 20:09:36 +02:00
Holger Vogt
4e03efacb7
Use InpEvaluate() instead of strtod to enable ngspice numbers
...
with scale factors Meg k m u n p f etc.
2021-09-29 20:09:22 +02:00
Holger Vogt
3be5926f2c
Reverse stepsize and finaltime in optran command,
...
stepsize first as in tran command.
2021-09-29 20:08:51 +02:00
Holger Vogt
bca099ca29
prevent crash if first breakpoint is beyond optran max time
2021-09-29 20:08:28 +02:00
Holger Vogt
6bdd6610f6
add tran simulation
2021-09-29 20:08:03 +02:00
Holger Vogt
b07a54b8e1
test of supply ramping
2021-09-29 20:07:42 +02:00
Holger Vogt
89f78bfc6c
updates to optran description and example.
2021-09-29 20:06:53 +02:00
Holger Vogt
7de526237e
upon finishing 'optran', restore old CKTstep
...
remove unused
2021-09-29 20:06:35 +02:00
Holger Vogt
0eafec254e
safeguard command 'optran' against circuit no being loaded
2021-09-29 20:05:56 +02:00
Holger Vogt
cf61e1e564
add missing header
2021-09-29 20:05:28 +02:00
Holger Vogt
83e223fafc
header for optran
2021-09-29 20:05:08 +02:00
Holger Vogt
29dfa23465
Pass Labs F5 Turbo
...
example for optran
2021-09-29 20:04:48 +02:00
Holger Vogt
a20afc54a5
When we sre ready, reset CKTmaxstep to its previous value
2021-09-29 20:04:26 +02:00
Holger Vogt
3956095484
set maxstepsize to stepsize
2021-09-29 20:04:08 +02:00
Holger Vogt
ecdb3b9eb4
set the task values, not the ckt values,
...
because task is called only afterwards when
the simulation command is given.
2021-09-29 20:03:31 +02:00
Holger Vogt
72c72268c5
fix some text entry
2021-09-29 20:02:47 +02:00
Holger Vogt
9c600c3265
short description of branch contents
2021-09-29 20:02:24 +02:00
Holger Vogt
fd36eb552f
set stepsize
2021-09-29 20:02:11 +02:00
Holger Vogt
ab6224767b
Add command 'optran' to set 6 flags for transient op
2021-09-29 20:01:44 +02:00
Holger Vogt
4dac35bac9
optran.c also in MSVC
2021-09-29 20:00:50 +02:00
Holger Vogt
df0792818f
Transient op calculation added to the standard operating point code.
...
When standard iteration, gmin stepping and source stepping fail,
try a transient simulation (like tran with uic option) to
determine the op. Implemented for AC and Tran simulation.
2021-09-29 20:00:29 +02:00
Holger Vogt
a08e6a0676
Add new SOA parameters (safe operating area) for BJT.
...
We now scan for max of Ic, Ib, power, taking into
account the max allowed temperature, using the thermal
resistance rth0 model parameter between juntion and ambient.
Two user options are there: If rth0 is given, we calculate
a derating of the max power allowed.
Without a constant max power according to model param pow_max
is assumed.
The new model parameters for the bipolar model are:
pow_max, ic_max, ib_max, te_max, and rth0, in addition
to the already existing vbe_max, vbc_max, adn vce_max.
2021-09-29 19:59:58 +02:00
Holger Vogt
1084b4205c
Allow global .temp in addition to instance parameter 'temp'.
...
Update to comments.
2021-09-29 19:59:28 +02:00
Holger Vogt
cbb63215c4
Remove the old SOA examples
2021-09-29 19:59:03 +02:00