manta/test/test_bridge_tx_sim.py

66 lines
1.9 KiB
Python

from amaranth.sim import Simulator
from manta.uart import TransmitBridge
from manta.utils import *
from random import randint, sample
bridge_tx = TransmitBridge()
def verify_encoding(data, bytes):
"""
Place a read response on the internal bus, and verify that the sequence of bytes
sent from TransmitBridge matches the provided bytestring `bytes`.
This function also models an ideal UARTTransmitter module, which begins transmitting
bytes when `start` is asserted, and reports when it is done by asserting `done`.
"""
# Place a read response on the internal bus
yield bridge_tx.data_i.eq(data)
yield bridge_tx.valid_i.eq(1)
yield bridge_tx.rw_i.eq(0)
yield bridge_tx.done_i.eq(1)
yield
yield bridge_tx.data_i.eq(0)
yield bridge_tx.valid_i.eq(0)
yield bridge_tx.rw_i.eq(0)
yield
# Model the UARTTransmitter
sent_bytes = b""
iters = 0
while len(sent_bytes) < len(bytes):
# If start_o is asserted, set done_i to zero, then delay, then set it back to one
if (yield bridge_tx.start_o):
yield bridge_tx.done_i.eq(0)
sent_bytes += (yield bridge_tx.data_o).to_bytes(1, "big")
yield bridge_tx.done_i.eq(0)
for _ in range(10):
yield
yield bridge_tx.done_i.eq(1)
yield
# Time out if not enough bytes after trying to get bytes 15 times
iters += 1
if iters > 15:
raise ValueError("Timed out waiting for bytes.")
# Verify bytes sent from ReceiveBridge match expected_bytes
if sent_bytes != bytes:
raise ValueError(f"Received {sent_bytes} instead of {bytes}.")
@simulate(bridge_tx)
def test_some_random_values():
for i in sample(range(0xFFFF), k=5000):
expected = f"D{i:04X}\r\n".encode("ascii")
print(i)
yield from verify_encoding(i, expected)