where devices extracted as "device resistor" or "device capacitor"
and defining parameters (e.g., area, perimeter) will generate the
device arguments in the wrong order in the .ext file, resulting in
incorrect readback when attempting to do ext2spice, resulting in the
device being omitted from the resulting netlist.
extraction times, which is an incorrect units conversion of the
"step" parameter in the extract section. It was converting based
on the "lambda" parameter in the same section, which has to do with
the scaling of values in the output file, not the scale factor of
the database to be extracted, which is set by the current CIF output
scale. Once fixed, extraction times are minimized using the rule of
thumb mentioned in the techfile reference, which is 50 times the
minimum feature size. Also: Give the lengthy nature of extraction
on large designs no matter how well optimized, added a feature to
mark the progress of the extraction in increments of 5%. Does not
output progress for small cells that extract quickly.
all the settings normally used for LVS (hierarchy on, cthresh
infinite, subcircuit top auto, etc.). (2) Extract and extract
unique ignore cells marked as abstract views (property LEFview
is set) when checking for unconnected nets with the same name
label.
in the SPICE netlist when using new device "csubcircuit" due to
a mismatch in the expected number of parameters. However, more
work needs to be done to cover capacitor top and bottom plates on
different planes.
added a long time ago, since capacitors use a different method for
calculating width and length than either transistors or resistors,
so subcircuits need a special class designator or else the extraction
may calculate the wrong dimensions for device width by totalling the
perimeter between the device and terminal types, as it would for a
MOSFET.
development had been halted since it was first created back in April.
Version 8.2 is now the official development version, with the first
development push to create a Cairo graphics interface.