cktdojob.c, add missing evaluation of TEMPER after new temperature is set
This is relevant for model and device parameters containing TEMPER.
This commit is contained in:
parent
67e06bb4ac
commit
648de2a001
|
|
@ -112,6 +112,12 @@ CKTdoJob(CKTcircuit *ckt, int reset, TSKtask *task)
|
||||||
|
|
||||||
fprintf(stdout, "Doing analysis at TEMP = %f and TNOM = %f\n\n",
|
fprintf(stdout, "Doing analysis at TEMP = %f and TNOM = %f\n\n",
|
||||||
ckt->CKTtemp - CONSTCtoK, ckt->CKTnomTemp - CONSTCtoK);
|
ckt->CKTtemp - CONSTCtoK, ckt->CKTnomTemp - CONSTCtoK);
|
||||||
|
|
||||||
|
/* call altermod and alter on device and model parameters assembled in
|
||||||
|
devtlist and modtlist (if using temper) because we have a new temperature */
|
||||||
|
if (expr_w_temper)
|
||||||
|
inp_evaluate_temper();
|
||||||
|
|
||||||
error = 0;
|
error = 0;
|
||||||
|
|
||||||
if (reset) {
|
if (reset) {
|
||||||
|
|
|
||||||