mirror of
https://github.com/RTimothyEdwards/magic.git
synced 2026-08-29 09:30:46 +02:00
NaN results for devices which are not FETs (specifically, devices that are declared using "msubckt" but are not FETs, although there may have been a related issue with non-FET devices not getting the correct M count), due to the device having zero measured width or length. NOTE: This may need more investigation. If a subcircuit device's method of merging cannot be understood, then such devices should never extract with "merge aggressive", and should always merge conservatively if and only if all parameters match.