Add vvp flag that allows $stop to act like $finish.

This patch adds a new flag to vvp "-n" that can be used to make
$stop and hence <Control-C> act like $finish. This may be desired
when using vvp in a non-interactive environment.
This commit is contained in:
Cary R 2007-12-29 22:26:02 -08:00 committed by Stephen Williams
parent 8ea3b6b0b8
commit d95c77a58a
3 changed files with 22 additions and 27 deletions

View File

@ -144,6 +144,7 @@ int main(int argc, char*argv[])
const char *logfile_name = 0x0;
FILE *logfile = 0x0;
extern void vpi_set_vlog_info(int, char**);
extern bool stop_is_finish;
#ifdef __MINGW32__
/* In the Windows world, we get the first module path
@ -159,7 +160,10 @@ int main(int argc, char*argv[])
}
#endif
while ((opt = getopt(argc, argv, "+hl:M:m:sv")) != EOF) switch (opt) {
/* For non-interactive runs we do not want to run the interactive
* debugger, so make $stop just execute a $finish. */
stop_is_finish = false;
while ((opt = getopt(argc, argv, "+hl:M:m:nsv")) != EOF) switch (opt) {
case 'h':
fprintf(stderr,
"Usage: vvp [options] input-file [+plusargs...]\n"
@ -169,6 +173,7 @@ int main(int argc, char*argv[])
" -M path VPI module directory\n"
" -M - Clear VPI module path\n"
" -m module Load vpi module.\n"
" -n Non-interctive ($stop = $finish).\n"
" -s $stop right away.\n"
" -v Verbose progress messages.\n" );
exit(0);
@ -186,6 +191,9 @@ int main(int argc, char*argv[])
case 'm':
module_tab[module_cnt++] = optarg;
break;
case 'n':
stop_is_finish = true;
break;
case 's':
schedule_stop(0);
break;

View File

@ -43,6 +43,7 @@
#endif
struct __vpiScope*stop_current_scope = 0;
bool stop_is_finish; /* When set, $stop acts like $finish (set in main.cc). */
#ifndef USE_READLINE
static char* readline_stub(const char*prompt)
@ -474,6 +475,13 @@ static void invoke_command(char*txt)
void stop_handler(int rc)
{
/* The user may be running in a non-interactive environment, so
* they want $stop and <Control-C> to be the same as $finish. */
if (stop_is_finish) {
schedule_finish(0);
return;
}
vpi_mcd_printf(1,"** VVP Stop(%d) **\n", rc);
vpi_mcd_printf(1,"** Current simulation time is %" TIME_FMT "u ticks.\n",
schedule_simtime());
@ -503,29 +511,3 @@ void stop_handler(int rc)
vpi_mcd_printf(1,"** Continue **\n");
}
/*
* $Log: stop.cc,v $
* Revision 1.16 2006/06/18 04:15:50 steve
* Add support for system functions in continuous assignments.
*
* Revision 1.15 2005/11/25 18:35:38 steve
* stop/continue messages go through MCD for logging.
*
* Revision 1.14 2005/09/20 18:34:02 steve
* Clean up compiler warnings.
*
* Revision 1.13 2005/01/29 06:29:17 steve
* Support interactive mode even without readline.
*
* Revision 1.12 2004/10/04 01:10:59 steve
* Clean up spurious trailing white space.
*
* Revision 1.11 2004/02/21 00:44:34 steve
* Add load command to interactive stop.
* Support decimal constants passed interactive to system tasks.
*
* Revision 1.10 2003/11/07 05:58:02 steve
* Fix conditional compilation of readline history.
*/

View File

@ -41,6 +41,11 @@ the module. However, if the name includes at least one directory
character, then the search path is not scanned and the name is assumed
to be a complete file name.
.TP 8
.B -n
This flag makes $stop or a <Control-C> a synonym for $finish.
It can be used to give the program a more meaningful interface when
running in a non-interactive environment.
.TP 8
.B -s
Stop. This will cause the simulation to stop in the beginning, before
any events are scheduled. This allows the interactive user to get