<col2_width>" to set the output format width, to avoid the fixed column
widths of 41 characters which can truncate long strings in the output
such as deep cell hierarchies. This command can be placed in the setup
script to widen the output columns to accomodate the result (to-do:
provide an "auto" mode to automatically determine the best width).
the possibility that a device (e.g., resistor or capacitor) may
not be a semiconductor device (in other words, a parasitic or
ideal device), and therefore uses "value" but not width and
length, and therefore "value" is a critical property to merge
both in series and parallel. Corrected the series/parallel
network optimization to prevent it from setting both M and S
records > 1 on the same device (which is ambiguous). To try
to get number of devices to match, where there are both series
and parallel devices, they will be merged across the critical
property early (before property matching).
'ignore class', but removes instances of the specified class whose
pins are shorted together. Currently requires that all pins must
be shorted together.